About EEGSimLab
Critical care EEG on your phone. Every EEG is synthetic.
An educational simulator for learning critical care EEG patterns, one pattern at a time, with the ACNS 2021 terminology. Every EEG in it is synthetic, and it uses no patient data.
Created by
Waleed Abood, MD
Neurologist and Epileptologist, Assistant Professor of Neurology/Epilepsy
Contributors
- Noor Abdulla, MD
- Lana Alamat, MD
- Mohamad Alsalih, MD
How it was built
EEGSimLab's code was written entirely with an AI coding assistant, Claude Code (Anthropic). The author directed the work and chose the clinical content, models and sources listed below. Every commit records the assistant as co-author, and the code is checked by an automated test suite.
The page uses no third-party libraries, fonts or icon sets: the icons are drawn for EEGSimLab, and text uses the device's system font.
Sources and credits
EEGSimLab builds on the published work below. Names, definitions and cut-offs are given in our own words.
EEG terminology, montages and sleep
- Hirsch LJ, Fong MWK, Leitinger M, LaRoche SM, et al. American Clinical Neurophysiology Society's Standardized Critical Care EEG Terminology: 2021 version. J Clin Neurophysiol. 2021;38(1):1–29. doi:10.1097/WNP.0000000000000806
- Acharya JN, Hani AJ, Cheek J, Thirumala P, Tsuchida TN. American Clinical Neurophysiology Society Guideline 2: guidelines for standard electrode position nomenclature. J Clin Neurophysiol. 2016;33(4):308–311. Electrode names (10-10 system). doi:10.1097/WNP.0000000000000316
- Acharya JN, Hani AJ, Thirumala PD, Tsuchida TN. American Clinical Neurophysiology Society Guideline 3: a proposal for standard montages to be used in clinical EEG. J Clin Neurophysiol. 2016;33(4):312–316. doi:10.1097/WNP.0000000000000317
- Kane N, Acharya J, Beniczky S, et al. A revised glossary of terms most commonly used by clinical electroencephalographers and updated proposal for the report format of the EEG findings. Revision 2017. Clin Neurophysiol Pract. 2017;2:170–185. The IFCN criteria for epileptiform discharges, and the N3 and sleep-spindle numbers. doi:10.1016/j.cnp.2017.07.002
- Kural MA, Duez L, Sejer Hansen V, et al. Criteria for defining interictal epileptiform discharges in EEG: a clinical validation study. Neurology. 2020;94(20):e2139–e2147. doi:10.1212/WNL.0000000000009439
- Kural MA, Tankisi H, Duez L, et al. Optimized set of criteria for defining interictal epileptiform EEG discharges. Clin Neurophysiol. 2020;131(9):2250–2254. doi:10.1016/j.clinph.2020.06.026
- Silber MH, Ancoli-Israel S, Bonnet MH, et al. The visual scoring of sleep in adults. J Clin Sleep Med. 2007;3(2):121–131. Stages 3 and 4 merged into N3. doi:10.5664/jcsm.26814
- Iber C, Ancoli-Israel S, Chesson AL, Quan SF. The AASM Manual for the Scoring of Sleep and Associated Events: Rules, Terminology and Technical Specifications. 1st ed. American Academy of Sleep Medicine; 2007. The N3 scoring rule: frontal 0.5–2 Hz waves over 75 µV peak to peak in at least 20% of a 30-s epoch.
Head model and source modeling
- Rush S, Driscoll DA. EEG electrode sensitivity—an application of reciprocity. IEEE Trans Biomed Eng. 1969;16(1):15–22. The three-concentric-sphere head model (brain, skull, scalp) behind the dipole page and Source modeling. Source modeling's 0.0042 S/m skull option is this model's 1:80 skull-to-brain ratio. doi:10.1109/TBME.1969.4502598
- de Munck JC, Peters MJ. A fast method to compute the potential in the multisphere model. IEEE Trans Biomed Eng. 1993;40(11):1166–1174. The series expansion for a dipole in a multilayer sphere, in Cartesian form. EEGSimLab sums the plain series (64 terms) without the paper's speed-up. doi:10.1109/10.245635
- McCann H, Pisano G, Beltrachini L. Variation in reported human head tissue electrical conductivity values. Brain Topogr. 2019;32(5):825–858. Reported head conductivities. The dipole page uses illustrative values, 0.33 S/m for brain and scalp and 0.0125 S/m for skull; the paper's pooled means are 0.41 S/m for scalp and 0.02 S/m for whole skull. doi:10.1007/s10548-019-00710-2
Missing a credit?
EEGSimLab is an educational product. If you believe someone's work is used here without credit, please tell me: send feedback with the topic "Citation issue", or message me on LinkedIn or X. I will correct it promptly.
How to cite
EEGSimLab must not be used for clinical care: not to read a patient's EEG, make a diagnosis or guide treatment.
Educational use only. Not for clinical care.